TS UniRail: starting points for tiled pitched roofs.
The catalogue informs equipment selection, but structural calculations remain project-specific.
What to check first
Tehnosol's UniRail range is intended for pitched roofs with suitable coverings. Roof hooks are selected to match the covering and supporting structure. A similar tile shape does not automatically imply the same fastening method or sufficient clearance.
How loads are transferred
Loads must travel through modules, clamps, rails and fasteners into the load-bearing structure. The roof covering must not inadvertently carry forces from the hook. Design checks wind, snow, edge zones and the actual condition of timber or other supporting materials.
Installation details
Observe approved module clamping zones and rail joint instructions. Connections between different metals and roof penetrations must be handled appropriately. Replacing one component with a similar-looking part can affect the compliance of the entire system.
Before ordering
Prepare a description of the covering, supporting-member spacing and condition, and module layout. Request an up-to-date bill of components and instructions for the selected items. Fastener quantities must follow an assessment, not a universal per-module rule.