Strokovni članki

How is the appropriate size of a solar PV installation determined?

The size of a solar PV installation depends on more than the number of photovoltaic modules that can fit on the roof. Electricity consumption and when it occurs, the ch …

Strokovni članki

Why is a 15-minute consumption profile more useful than an annual bill alone?

Annual or monthly electricity consumption figures are useful, but they do not reveal when the energy was needed. Two sites may use exactly the same amount of electricit …

Strokovni članki

How can actual electricity consumption be calculated with PV and battery storage?

Illustrative example — synthetic data, not measurements from a real site. All figures below are energy values at the same reference boundary of the AC system, recorded …

Vprašanja in odgovori

What is the difference between kW and kWh?

kW describes power at a particular moment, or average power over an interval; kWh describes an amount of energy over time. A 10 kW system operating at full load for one …

Vprašanja in odgovori

What is reactive power?

Reactive power occurs in alternating-current electrical systems with inductive or capacitive loads. It affects currents, loading and, in some cases, costs; it is not th …

Vprašanja in odgovori

Why is power factor important?

Power factor relates active power to apparent power. An unsuitable power factor can mean higher currents and additional technical requirements, so it is monitored for m …

Vprašanja in odgovori

Why can a meter record both imports and exports on the same day?

Because electricity flow does not always go in the same direction: a building imports electricity at some times and exports it at others. Daily totals do not show wheth …

Vprašanja in odgovori

What is the difference between connection capacity and billing demand?

Connection capacity follows from the grid-connection conditions, while billing demand is determined under the relevant network charging rules. They are not necessarily …

Vprašanja in odgovori

What does three-phase loading mean?

In a three-phase system, the distribution of load between phases matters as well as the total power. Uneven loading can cause problems even when total power is not high …

Vprašanja in odgovori

Does 15-minute demand show the highest instantaneous current?

No. Calculated 15-minute demand is an average over a quarter of an hour; short inrush currents and instantaneous peaks may be higher.

Vprašanja in odgovori

When is a more advanced power quality analyzer needed?

When investigating the causes of voltage drops, disturbances, harmonics, imbalance or brief transients that standard billing data cannot reveal.

Vprašanja in odgovori

Why is annual consumption insufficient for sizing a solar PV system?

Two businesses with the same annual electricity consumption may need energy at very different times. Matching the timing of generation and consumption has a major effec …

Vprašanja in odgovori

Why is a 15-minute load profile important when sizing battery storage?

It shows the duration, timing and recurrence of demand peaks as well as available charging windows. Without this information, a system may have insufficient power, too …

Vprašanja in odgovori

How is average power calculated from 15-minute energy data?

Divide the energy recorded for the interval in kWh by 0.25 hours; the result is in kW. For example, 12 kWh in a quarter of an hour corresponds to 48 kW of average power …

Vprašanja in odgovori

How many readings are recorded in a full year?

At the usual 15-minute sampling interval, there are 96 intervals per day, or approximately 35,040 readings over 365 days. Check timestamps, daylight-saving transitions …

Vprašanja in odgovori

What is the difference between a building's total consumption and its grid imports?

Grid imports represent only the electricity drawn through the grid connection. With solar PV and battery storage, a building's total consumption may also include electr …

Vprašanja in odgovori

Why can an average daily load profile be misleading?

An average conceals individual high peaks, weekends, production cycles and infrequent events. Sizing should also examine variability and exceptional days.

Vprašanja in odgovori

How can the quality of metering data be checked?

Check units, intervals, time zone, missing points, duplicate readings, the direction of imports and exports, and the meter's position in the building's electrical confi …