How is the appropriate size of a solar PV installation determined?
The size of a solar PV installation depends on more than the number of photovoltaic modules that can fit on the roof. Electricity consumption and when it occurs, the ch …
Practical explanations of solar PV, battery storage, heating, EV charging and energy management.
Select a subject or search for an article, question or technical term.
The size of a solar PV installation depends on more than the number of photovoltaic modules that can fit on the roof. Electricity consumption and when it occurs, the ch …
Annual or monthly electricity consumption figures are useful, but they do not reveal when the energy was needed. Two sites may use exactly the same amount of electricit …
Illustrative example — synthetic data, not measurements from a real site. All figures below are energy values at the same reference boundary of the AC system, recorded …
kW describes power at a particular moment, or average power over an interval; kWh describes an amount of energy over time. A 10 kW system operating at full load for one …
Reactive power occurs in alternating-current electrical systems with inductive or capacitive loads. It affects currents, loading and, in some cases, costs; it is not th …
Power factor relates active power to apparent power. An unsuitable power factor can mean higher currents and additional technical requirements, so it is monitored for m …
Because electricity flow does not always go in the same direction: a building imports electricity at some times and exports it at others. Daily totals do not show wheth …
Connection capacity follows from the grid-connection conditions, while billing demand is determined under the relevant network charging rules. They are not necessarily …
In a three-phase system, the distribution of load between phases matters as well as the total power. Uneven loading can cause problems even when total power is not high …
No. Calculated 15-minute demand is an average over a quarter of an hour; short inrush currents and instantaneous peaks may be higher.
When investigating the causes of voltage drops, disturbances, harmonics, imbalance or brief transients that standard billing data cannot reveal.
Two businesses with the same annual electricity consumption may need energy at very different times. Matching the timing of generation and consumption has a major effec …
It shows the duration, timing and recurrence of demand peaks as well as available charging windows. Without this information, a system may have insufficient power, too …
Divide the energy recorded for the interval in kWh by 0.25 hours; the result is in kW. For example, 12 kWh in a quarter of an hour corresponds to 48 kW of average power …
At the usual 15-minute sampling interval, there are 96 intervals per day, or approximately 35,040 readings over 365 days. Check timestamps, daylight-saving transitions …
Grid imports represent only the electricity drawn through the grid connection. With solar PV and battery storage, a building's total consumption may also include electr …
An average conceals individual high peaks, weekends, production cycles and infrequent events. Sizing should also examine variability and exceptional days.
Check units, intervals, time zone, missing points, duplicate readings, the direction of imports and exports, and the meter's position in the building's electrical confi …