Good energy data: units, time and missing values.
A data error can lead to the wrong investment.
Units and meaning
Distinguish energy per interval from average power. Over a 15-minute interval, an average power of 4 kW corresponds to 1 kWh of energy. Also verify import and export signs and whether the data describe the whole site or a single device.
Timestamps
Data must have a known time zone and daylight-saving-time convention. Determine whether each timestamp indicates the start or end of an interval. Misaligned clocks can incorrectly match consumption to prices and generation.
Missing is not zero
A missing measurement is not evidence of zero consumption. Estimates and substituted values should be flagged. When analysing data, report the share of missing intervals and assess how replacements affect the result.
Checks before simulation