A declaration of performance is not a structural calculation for your roof.
Understand what a declaration establishes—and what it does not.
A declaration applies to a defined product
A declaration of performance describes declared characteristics of a product within its stated intended use. Check product designation, purpose, version and the basis for the declaration. Documentation for a different rail or assembly is not automatically applicable.
NPD is not a numeric load capacity
Where performance has not been declared for a characteristic, the document cannot be used to derive structural load capacity. Request relevant data, instructions or calculations for the actual application. Structural verification must cover the complete load path.
Material and complete assembly
A material's reaction-to-fire class does not demonstrate the fire performance of an entire roof, façade or PV installation. This depends on all layers and the way they are assembled. Likewise, a certificate for one component does not replace verification of its connections to other components.
Evidence file
At project handover, retain current declarations, instructions, drawings and records of installed components. When replacing a part later, check whether the new component remains within the approved combination and design assumptions.